comparison of particulate mercury measured with manual and automated methods比较的颗粒汞用手动和自动测量方法.pdf
文本预览下载声明
Atmosphere 2011, 2, 1-20; doi:10.3390/atmos2010001
OPEN ACCESS
atmosphere
ISSN 2073-4433
/journal/atmosphere
Article
Comparison of Particulate Mercury Measured with Manual and
Automated Methods
1, 1 1,2 3 1
Robert Talbot *, Huiting Mao , Dara Feddersen , Melissa Smith , Su Youn Kim ,
Barkley Sive 1, Karl Haase 1,2, Jesse Ambrose 1, Yong Zhou 1 and Rachel Russo 1
1 Climate Change Research Center, Institute for the Study of Earth, Oceans, and Space, University of
New Hampshire, Durham, NH 03824, USA; E-Mails: hmao@ (H.M.);
dmy49@ (D.F.); sk@ (S.Y.K.); bcs@ (B.S.);
khaase@ (K.H.); jambrose@ (J.A.); yzhou@ (R.Z.);
rrusso@ (R.R.)
2 Department of Chemistry, University of New Hampshire, Durham, NH 03824, USA
3 Department of Earth Science, University of New Hampshire, Durham, NH 03824, USA;
E-Mail: htimsyssim@
* Author to whom correspondence should be addressed; E-Mail: robert.talbot@;
Tel.: +1-603-862-1546; Fax: +1-603-862-2124.
Received: 2 December 2010; in revised form: 30 December 2010 / Accepted: 15 January 2011 /
Published: 20 January 2011
P
Abstract: A study was conducted to compare measuring particulate mercury (Hg ) with
the manual filter method and the automated Tekran system. Simultaneous measurements
were conducted with the Tekran and Teflon filter methodologies in the marine and coastal
continental atmospheres. Overall, the