《A Single-Phase Grid-Connected PV System 》.pdf
文本预览下载声明
INTERNATIONAL JOURNAL of CIRCUITS, SYSTEMS and SIGNAL PROCESSING
Issue 1, Volume 2, 2008
A Single-Phase Grid-Connected PV System
With Active Power Filter
Denizar C. Martins and Kleber C. A. de Souza
fed to the utility. The balance of power flow is controlled
Abstract—In this paper a single-phase active power filter based through the inverter. The inverter also is used to act always as
in a two stages grid-connected photovoltaic system is presented. The an active power filter to compensate the load harmonics and
proposed system can not only inject PV power into utility but can act reactive power such that the input power factor is unity (Fig.
always as an active power filter to compensate the load harmonics 2).
and reactive power such that the input power factor is unity
independently of the solar radiation. In sunny days, the system
processes all the reactive and active load power and the excessive II. PROCEDURE FOR PAPER SUBMISSION
power from the PV module can be fed to the utility. On the other The dc-dc converter power structure used to boost the PV
hand, on cloudy days for instance, if the PV power is not enough, the voltage and for tracking the maximum power point of the PV
system processes all the reactive load power and the shortage of load
modules to fully utilize the PV power was the Half-Bridge
active power is supplemented by the utility. Besides, just using one
current sensor, the control strategy is simpler
显示全部