《《A Single-Phase Grid-Connected Inverter with a Power Decoupling Function》.pdf
文本预览下载声明
A Single-Phase Grid-Connected Inverter with a
Power Decoupling Function
Fumihiro Shinjo, Keiji Wada, Toshihisa Shimizu
Department of Electrical and Electronic Engineering
Tokyo Metropolitan University
1-1, Minamiosawa, Hachioji, Tokyo, 192-0397, Japan
Abstract— This paper presents a single-phase grid connected SX2 Lf
inverter with a power decoupling circuit. In the single-phase grid SAC 1 SAC3
connected inverter, it is well known that a power pulsation with power decoupling SM2 L iAC
twice the grid frequency is contained in the input power. In a con- iDC circuit s
ventional inverter, electrolytic capacitors with large capacitance Cf vAC
have been used in order to smooth the DC voltage. However, SX0 vX CX SX 1 SAC2 SAC4
lifetime of those capacitors is shortened by the power pulsation
vDC CDC
with twice grid frequency. The authors have been studied a active
power decoupling method that reduce the pulsating power on LX SM 1
the input DC bus line, this enables to transfer the ripple energy
appeared on the input DC capacitors into the energy in a small
film capacitor on the additional circuit. Hence, extension of the Fig. 1. Main circuit configration.
lifetime of the inverter can
显示全部