加筋挡土墙施工中问题及对策探讨.doc
文本预览下载声明
加筋挡土墙施工中问题及对策探讨
摘要:加筋土挡墙是由砌块、土工格栅和填料三部分组成的复合结构,依靠填料与土工格栅之间的摩擦力,抵抗预制块所受的水平土压力(即加筋土挡墙的内部稳定),并抵抗格栅尾部填料所产生的土压力(称为加筋土结构的外部稳定),从而保证了整个结构的稳定,加筋土挡墙的主要优点是施工简便、造价低廉、少占土地、造形美观,并且发展成很多形式。本文主要从加筋挡土墙施工中容易出现的问题、加筋土挡土墙设计过程中几个问题的讨论和加筋土挡墙施工要点和步骤进行了探讨。
关键词:加筋挡土墙;施工
Abstract: the retaining wall is by brick, grille and packing three part composite structure, rely on the packing friction between the grille, resist precast block were level soil pressure (or of the retaining wall internal stability), and resist the tail produced grille packing earth pressure (called the structure of reinforced external stability), so as to ensure the stability of the whole structure, the main advantages of the retaining wall is construction simple, low cost, less land and forms of beauty, and developed into many forms. This article mainly from the reinforcement retaining wall construction easily appeared problems, the reinforced soil retaining wall design process of some problems of discussions and retaining wall construction points and steps are discussed.
Keywords: reinforcement retaining wall; construction
中图分类号:TU74文献标识码:A 文章编号:
一、加筋挡土墙施工中容易出现的问题
采用钢筋植入和吊线锤,在加筋土挡墙施工过程中对墙面水平位移进行监控,通过设计角度,运用三角函数可轻松算得准确水平值,安装好预制块后测得初值施工中重点监控,尤其是晚间不施工段早晨开工前和傍晚收工前监控数据差值要严格审查。发现过大或突然变化位移,立即停止施工,可采取相应的施工补救措施,避免工程事故的发生。位移监控的具体方法是沿挡土墙边缘设置一条基线,运用三角网进行监控。加筋挡土墙施工完毕后位移变形监控至少持续一个雨季。修护期间,加筋挡土墙必然会出现沉降,填土与挡墙顶压顶混凝土间2m范围内为严控区域。此区域因沉降和雨季等其他影响,最易形成沟槽或其他形状汇水区,对填土质量是个重大考验,此区因在施工中压路机等机械设备不能靠近、人工夯实,宜采用不透水填料。在沉降过程中,施工人员要随时注意检查,尤其是雨后。
另外,常见质量通病有挡墙通缝、压顶混凝土倾覆、断裂等。此种通缝出现后,检查有无混凝土预制块断裂,如有需布设监控点,对通缝变化趋势进行监控,便于确定不均匀沉降程度。变化稳定的对墙体无明显影响的可以不进行重大处理,但外观需修整。变化还在继续无明显停止迹象的,要采用人工将钢筋混凝土基础挖出,确定有无断裂,严重时在合适位置增设沉降缝。此种质量通病由于局部填料人工夯实达不到要求引起,除施工时严格控制外,只有及时检查争取早发现,一旦发现立即处理,将压顶混凝土下填料压实密实,否则时间长会引起压顶混凝土断裂,挡墙顶几层混凝土预制块断裂,后果极严重。
二、加筋土挡土墙设计过程中几个问题的讨论
加筋土挡土墙设计内容主要包括以下两个方面: 1) 决定加筋土材料的种类、长度、横截面形式和间距; 2) 保证墙外部和内部稳定性。
下面就设计过程中的几个问题进行讨论。1) 筋带的选择。拉筋对于加筋土挡土墙至关重要,应具备较高的抗拉强度,有韧性,变形小,有较好的柔韧性,与填土之间有较大的摩擦力,抗腐蚀,便于制作,价格低廉。筋带一般由钢筋混凝土、土工格栅或钢板
显示全部