A Comparative Study of Commercial ATP (商业ATP的比较研究).pdf
文本预览下载声明
A Comparative Study of Commercial
ATP Hygiene Monitoring Systems
Abstract
The performance of 5 leading commercially available of ATP hygiene
monitoring systems were compared in the largest independent study of its kind.
Linearity, Sensitivity, Repeatability, Precision and Accuracy are the major
requirements of an effective ATP system. These performance criteria were
determined using many replicates and dilutions of ATP, foodstuffs and micro-
organisms.
The findings indicate that some of the systems show large variations and
background interference which significantly affects their ability to meet the
performance criteria.
The best system was revealed to be Hygiena SystemSURE Plus and the
poorest systems were Charm Novalum and Neogen Accupoint.
Overview
1. Scope of the study
Disclaimer:
2. Components of an ATP system
This presentation was prepared by Hygiena and is
3. Performance results based on studies criteria
solely based on data generated from the comparative
Section 1: ATP performance results study of ATP hygiene monitoring systems by Silliker
Section 2: Foodstuffs performance results Inc. Food Science Center Report RPN 13922
Section 3: Micro-organisms performance results (2010).This presentation contains all the conclusions
4. Universal ATP device performance – Snapshot drawn by Silliker and further detailed analysis of the
raw