燃煤机组锅炉给水泵配置方式的研究.doc
文本预览下载声明
300MW燃煤机组锅炉给水泵配置方式的研究
摘要
锅炉给水泵是火力发电厂的重要辅机,国内给水泵常用的驱动方式有小汽轮机驱动和液力耦合器调速电动机驱动两种。本文把大机与小机均湿冷的大型燃煤火力发电机作为研究对象,通过对 300MW火电机组汽动给水泵、电动给水泵配置标准的调研,提出全部为电动给水泵配置方式、全部为汽动给水泵配置方式、电动给水泵和汽动给水泵综合配置方式3种方案,采用定性分析和定量计算相结合的方法,对3种方案的经济性进行分析和计算得出结论。
关键词: 燃煤机组;给水泵;小汽轮机驱动;电动机驱动;经济性
300 MW COAL-FIRED UNIT BOILER FEED WATER PUMP CONFIGURATION MODE
ABSTRACT
Boiler feed pump is one of the most important auxiliary equipment in thermal power plant, the two main driving modes of feed pumps are motor-driven mode and steam-driven mode in China power stations. This paper takes large coal-fired generating unit with the big turbine and small turbine can cool by water as the object of study, investigated the two driving modes running situation and collocation standard, all proposed for electric feed water pump configuration mode, all for the steam feed pump configuration mode and steam feed water pump, electric pump is integrated configuration way three kinds of schemes, adopts the method of combining qualitative analysis and quantitative calculation, analysis and calculation of the economy of three kinds of schemes for the conclusion.
Key words: feed water pump; motor-driven; steam-driven; economy
目 录
1 绪论………………………..……………………………….……………………1
1.1 课题背景………………………………………………………………………
1.2 研究的目的和意义……………………………………
1.3 国内外研究现状……………………………………
1.4 课题研究内容 ……………………………………
2 给水泵的配置方式……………………………………
2.1 给水泵组的配置原则……………………………………
2.2 国内300MW机组给水泵组的配置情况调研分析……………………
2.2.1 国内给水泵配置情况……………………………………
2.2.2 国内300MW机组给水泵组的配置方式分析…………………………
2.2.3 备用给水泵的容量配置分析 ……………………………………
2.2.4 给水泵运行情况统计…………………
2.3 给水泵组的驱动方案……………………………………
3 热经济性比较………………………………………………………
3.1 火力发电厂的热经济性指标…………………
3.2 锅炉给水泵热经济性比较方法介绍…………………
3.2.1 比较两种方式的相对效率…………………
3.2.2 比较各自的输出净功率…………………
4 300MW机组不同配置方式经济性比较实例…………………
4.1 给水泵组驱动方案及配置情况…………………
4.2 主要热力参数…………………
4.2.1 主机的主要技术规范…………………
4.2.2 不同工况下的数据…………………
4.3 热力计算公式…………………
4.3.1 给水泵组的轴功率…………………
4.3.2 电动调
显示全部