NFPA 5000 -2024 Building Construction and Safety Code 建筑结构及安全守则(20-3).pdf
Astructureabovetheroofofanypartofabuildingenclosingastairway,a
tank,elevatormachine「y,se「viceequipment,orpa「tofashaftextending
abovetheroof,nothousinglivi『1g0『「ecreationalaccommodations.(BLD-BLC)
3.3.643.15TemporaryStructure.
Abuildingorstructu「enotmeetingthedefinitionofpermanentstructure.(See
also主主旦主旦PermanentStructure.)(BLD平UN)
3.3.643.16Tensioned-MembraneStructure.
Amembranestructureincorporatingamembraneandastructuralsupport
systemsuchasarches,columnsandcables,orbeamswhe「einthest「esses
developedinthetensionedmembraneinteractwiththoseinthestructural
supportsothattheentireassemblyactstogetherto「esisttheappliedloads.
(BLD态CM)
3.3.643.17*UndergroundStructure.
AstructureO「po「tionsofastructu「einwhichthefloo「levelislocatedmore
than30ft(9.1m)belowthelowestlevelwithanexitdischarge.(BLD州D)
3.3.643.18Water-SurroundedStructure.
Astructurefullysurroundedbywater.(BLD-IND)
3.3.644Structure(FloodResistance).
See豆豆豆主主1.
3.3.645Sub-MembraneDepressurizationSystem.
See3.3.651.4.3.
3.3.646SubstantialDamage(FloodResistance).
Fo「buildingsandst阳ctureslocatedwhollyorpartlywithinthefloodhazard
area,damageofanyO「iginwherebythecostofresto「ingthebuildingo「
structuretoitsp「e-damageconditionwouldequalorexceed50pe「centofthe
marketvalueofthebuildingorstructure.(BLD-SCM)
3.3.647SubstantialImprovement(FloodResistance).
Fo「buildingsandst「uctureslocatedwhollyorpartlywithinthefloodhazard
area:(1)anyrepair,addition,reconstruction,「ehabilitation,orimp「ovementof
thebuildingorstructure,thecostofwhichequalsorexceeds50pe「centof
thema「ketvalueofthebuildingo「structu「ebeforethealterationisstarted;or
(2)ifabuildingorst阳cturehassustainedsubstantialdamage,anyrepairsor
reconstruction,regardlessoftheactua