《Testing Procedures for SSL Products》.pdf
文本预览下载声明
Testing Procedures
for
Solid State Lighting Products
DOE SSL Market Introduction Workshop
July 9-11, 2008
Status of SSL Testing Procedures
• ANSI C78.377 - Specifications for the Chromaticity of
Solid State Lighting Products Published February 2008
• IES LM-79-08 - Electrical and Photometric
Measurements of Solid-State Lighting Products Published
May 2008
• IES LM-80 - Method for Measuring Lumen Maintenance
for SSL Light Sources Expected Summer 2008
Testing to IES LM-79-08
• Goniophotometry
• Integrating Sphere
(Photometry and
Spectrometry)
Goniophotometry - LM-79-08
• Absolute Photometry
• Type C Goniophotometer
• Color-Corrected Detector
Goniophotometry LM-79-08
• Luminous Intensity
Distribution
• Total Luminous Flux
• Zonal Lumen Sums
• IES Format File
Goniophotometry LM-79-08
The results can be used to • IES Format Files
predict the performance • Illuminance (Footcandles, Lux)
of the luminaire in its
• Average footcandles within a
application. space, max/min ratios, etc.
Relative Photometry
Luminaires that use conventional lighting sources are
usually tested using relative photometry.
• The luminaire is measured.
• The lamp(s) and ballast(s) are removed and
measured.
• Luminaire Efficiency can
显示全部