DB34_T4344-2022_高速公路恶劣气象条件监测站建设技术规范_安徽省.docx
ICS07.060
CCSA47
34
安徽省地方标准
DB34/T4344—2022
高速公路恶劣气象条件监测站建设技术规
范
Technicalspecificationforexpresswayseveremeteorologicalconditions
monitoringstationconstruction
安徽省市场监督管理局
发布
DB34/T4344—2022
目
次
前言.................................................................................II
1
2
3
4
5
6
范围...............................................................................1
规范性引用文件.....................................................................1
术语和定义.........................................................................1
布点与选址要求.....................................................................2
仪器布局与安装.....................................................................2
建设工作流程.......................................................................4
附录A(资料性)六要素自动气象站(标准式)仪器布局示意图.............................5
附录B(规范性)设备技术要求.........................................................6
参考文献..............................................................................9
I
DB34/T4344—2022
前
言
本文件按照GB/T1.1—2020《标准化工作导则第1部分:标准化文件的结构和起草规则》的规定
起草。
请注意本文件的某些内容可能涉及专利。本文件的发布机构不承担识别专利的责任。
本文件由安徽省气象局提出并归口。
本文件起草单位:安徽省大气探测技术保障中心、芜湖市气象局。
本文件主要起草人:吴健、陆斌、张丽、沈玉亮、董德保、孙大兵、方海涛、黄皓、朱亚宗、张广
元、章超。
II
DB34/T4344—2022
高速公路恶劣气象条件监测站建设技术规范
1
范围
本文件规定了高速公路恶劣气象条件监测站建设的布点与选址、仪器布局与安装、建设工作流程等
要求。
本文件适用于安徽省高速公路恶劣气象条件监测站的建设和管理。
2
规范性引用文件
下列文件中的内容通过文中的规范性引用而构成本文件必不可少的条款。其中,注日期的引用文件,
仅该日期对应的版本适用于本文件;不注日期的引用文件,其最新版本(包括所有的修改单)适用于本
文件。
GB/T31162
地面气象观测场(室)防雷技术规范
GB/T33703—2017
自动气象站观测规范
QX/T291
QX/T465
自动气象站数据采集器现场校准方法
区域自动气象站维护技术规范
3
下列术语和定义适用于本文件。
高速公路恶劣气象条件监测站expresswayseveremeteorologicalconditionsmonitoring
station
在高速公路沿线或服务区布设的、反映高速公路恶劣气象条件的自动气象站,其对高速公路沿线的
单能见度站visibilitymonitoringstation
监测要素包括能见度、气温、湿度、风向、风速和雨量的自动气象站,分为标准式和集成式两种。
其中标准式主要布设在高速公路服务区、收费站,集成式主要布设在高速公路沿线。
1
DB34/T4344—2022
4
布点与选址要求
布点要求
监测站的布点应满足以下要求:
a)
监测站平均间距为15km;遇有山峰、峡谷、陡坡、急转弯道等地市突变情况时,监测站的建
设可不受平均间距限制;
b)
对于大雾频发且路段相对固定,或曾因大雾天气造成重、特大事故的个别路段,监测站可加密
至3km;
c)
d)