横河AM012 Calibrator电磁流量计技术说明书.pdf
ContentsIndex
GeneralModelAM012
SpecificationsMagneticFlowConverter
GS1E6K2-E
OUTLINE
AMO12isasignalgeneratorusedtocheckthecalibration
andoperationofAM11MAGNETICFLOWCONVERTERS,
AM12MAGNETICFLOWCONVERTERS,
AM100A/200A-INTEGRALTYPEMAGNETICFLOWMETER,
YMA11MAGNETICFLOWCONVERTER,COMPACT
YEWMAGMAGNETICFLOWMETER(styleAandstyleB)
andADMAGAEMAGNETICFLOWMETER.
Astheexcitationloadisbuild-in,thecalibrationand
operationofaconvertercanbecheckedwithoutadetector.
Spancanbesetwithintherangeofflowrates0to10m/s.
Outputsignalcorrepondingtosettingspancanbesetto0,
25,50,75,100%withthesettingdial.
PowerCode
STANDARDSPECIFICATIONSPowerplugisattachedasdescribedbelow.
Case:
Material:Polyesterresin
Size:110(height)x235(width)x364(rear)mm.
Color:Lightgrayishgreen.
ConnectingCable:PowercordforAM012.
Signalcable.
Excitationcable.
SettingRanges:
SpanSettingDial:0to10m/s(minimumspan0.01m/s).
OPTIONALSPECIFICATION
OutputSettingDial:CHECK,0,25,50,75,100%.
Accuracy:CableforCompactYEWMAG
0.1m/sormore:+0.04%ofsetvalue.ForthecalibrationofCompactYEWMAG.
0.1m/sorless:Flowrateof+0.04mm/s.Withtheconnectorforsignalandexcitationcable.
Power:90to132VACor180to264VAC,47to63HzOptioncode/CYM
AmbientTemperature:0to40JunctionboxforADMAGAE