建筑试验取样方法与取样数量详解.doc
文本预览下载声明
建筑试验取样方法与取样数量
培训讲义
见证取样试验室
2016年1月
目 录
1. 水泥检验试验取样标准············································································(1)
2. 砂子检验试验取样标准············································································(2)
3. 石子检验试验取样标准············································································(3)
4. 钢材检验试验取样标准············································································(4)
5. 钢筋焊接(机械连接)接头检验试验取样标准········································(6)
6. 砌墙砖和砌块检验试验取样标准····························································(8)
7. 普通砼检验试验取样标准········································································(9)
8. 砌筑砂浆检验试验取样标准··································································(11)
9. 粉煤灰检验试验取样标准······································································(12)
10. 外加剂检验试验取样标准····································································(13)
11. 回填土工程检验试验取样标准····························································(16)
1 水泥检验试验取样标准
1.1 散装水泥应以同一水泥厂、同期出厂的、同品种、同标号、以一次进厂(场)的同一出厂编号的水泥每500t为一批,不足亦为一批。
1.2 袋装水泥应以同一水泥厂、同期出厂的、同品种、同标号、一次进厂(场)的同一出厂编号的水泥每200t为一批,不足亦为一批。
1.3 每一验收批取样时,散装水泥应从3个以上罐车中采取等量的水泥,混合均匀后从中称取不少于12kg水泥作为检验试样。袋装水泥从不少于20袋中采取等量样品,经混拌均匀后,称取不少于12kg水泥作为检验试样。
1.4 对于存放超过三个月的常用水泥,使用前必须按规定重新取样复验。并按复验结果使用。
注:标准摘自GB175―2007
GB12573―2008。
2 砂子检验试验取样标准
2.1 砂子应以同产地、同规格、同进厂时间,每400m3或600t为一验收批,不足亦为一批。
2.2 每一验收批取一组砂样38kg。
2.3 在料堆上取样时,取样部位均匀分布,取样先将取样部位表层铲除,由各部位抽取大致相等的试样8份(每份11kg以上),搅拌均匀后用四分法缩分至38kg组成一组试样。
2.4 从皮带运输机上取样时,应在皮带运输机机尾的出料处,用接料器定时抽取试样,由4份试样(每份20kg以上),搅拌均匀后用四分法缩于38kg组成一组试样。
注:标准摘自:JGJ52-2006
GB/T14684-2001
3 石子检验试验取样标准
3.1 石子应以同产地、同规格、同进厂时间每400m3或600t为一验收批,不足亦为一批。
3.2 每一验收批取一组石子样数量为60kg(最大料径40mm、31.5mm)或40kg(最大料径≤20mm)
3.3 在料堆上取样时,取样部位均匀分布,取样先将取样部位表层铲除,由各部位抽取。大致相等的石子试样16份,组成一组样品。
3.4 从皮带运输机上取样时,应在皮带运输机尾的出料处,用接料器定时抽取8份组成一组样品。
注:标准摘自JGJ52-2006
GB/T14685-2001
4 钢材检验试验取样标准
4.1 钢筋砼用热轧带肋钢筋,余热处理钢筋,热轧光圆钢筋的取样。
4.1.1 以同厂别、同炉号、同规格、同一交货状态,同一进厂的时间数量不大于60t钢筋为一
显示全部