BSC告警处理总结.pdf
文本预览下载声明
BSC 告警处理总结
王秀杰
2010-9-26
一、消传输告警
1.消 DIP 告警
DTQSR:DIP=ALL,ES,SES,SF;
DTQSR:DIP=ALL,ES2,SES2,SF;
DTQSR:DIP=ALL,UNACC,DEGR,SF;
2.消光纤告警
TPQSR:SDIP=,DEGR;
TPQSR:SDIP=,MS=MS-0,ES,ES2;
TPQSR:SDIP=,MS=MS-0,BBE,BBE2;
TPQSR:SDIP=,MS=MS-0,SES,SES2;
TPQSR:SDIP=,DEGR;
TPQSR:SDIP=,MS=MS-1,ES,ES2;
TPQSR:SDIP=,MS=MS-1,BBE,BBE2;
TPQSR:SDIP=,MS=MS-1,SES,SES2;
3.LAYER 为VC4-0
用以下来消
TPQSR:SDIP=,BBE,BBE2;
TPQSR:SDIP=,SES,SES2;
TPQSR:SDIP=,ES,ES2;
二、A1 级告警
1.光纤告警
注释:出现这种告警,可能是由于把割接用丌到的传输(没有做业务)给解开了,所以要将
传输给闭上 ,告警才会消除。
1
ALLIP:ACL=A1;
ALARM LIST
A1/APT JNBSC32/C33CA/0 806 100421 0010
SYNCHRONOUS DIGITAL PATH FAULT SUPERVISION 光纤告警
SDIP STATE LAYER K L M FAULT INFO DATE TIME
6ETM2 TRAFLIM VC12-0 1 1 1 UNEQ 100421 001028
TYPE PL/TTI ERDIINFO
先用 TPCOP:SNT=ETM2-6;查看对应的传输,看看哪些传输没有做业务,但是给解开了。
TPCOP:SNT=ETM2-6;
SYNCHRONOUS DIGITAL PATH DATA
SDIP SNT MS CLREF HP LP K L M DIP
6ETM2 ETM2-6 MS-0 VC4-0 VC12-0 1 1 1 39RBL2
MS-1 VC12-1 2 1 1 69RBL2
VC12-2 3 1 1 44RBL2
。。。。。。。
VC12-61 2 7 3 187RBL2
VC12-62 3 7 3 188RBL2
SDIP SDIPOWNER
6ETM2 SDIPM2
END
然后 TPSTP:SDIP=6ETM2;查看光纤的状态,发现 VC12-0 对应的传输应该是闭上的,所
以将其闭上。
TPSTP:SDIP=6ETM2;
SYNCHRONOUS DIGITAL PATH STATE
SDIP LAYER K L M STATE BLS FAULT TYPE PL/TTI
6ETM2 TRAFLIM SBL
MS-0 WO
MS-1
显示全部