单桩计算(Single pile calculation).doc
文本预览下载声明
单桩计算(Single pile calculation)
The drill number: ZK1
Pile type: prestressed pipe pile
Vertical load resistance factor: K = 2
Pile category: round pile
D/a = 400mm
Cross-sectional area As = 125663704 m
Perimeter L = 1m
The first soil layer is: silty clay, standard value of limit resistance
The depth is:.0m; The bottom depth is: -8m
Soil thickness h = 8 m
The liquefaction of the soil is psi L = 1
Limit side resistance Qsik = L * h * Qsik * psi L = 1.2566 3704 * 8 x 53 x 1 = 532KN
The 2nd soil layer is: silty clay, standard value qsik = 42Kpa
The depth is: -8m; The bottom depth is: -11m
Soil thickness h = 3 m
The liquefaction of the soil is psi L = 1
The limit side resistance Qsik = L * h * Qsik * psi L = 1.2566 3704 * 3 * 42 * 1 = 158KN
The third soil layer is: pebbles, the standard value of the limit side resistance qsik = 135Kpa
The depth is: -11m; The bottom depth is: -13.1 m
Soil thickness h = 2.1 m
The subsurface liquefaction coefficient, psi L = 1
The limit side resistance Qsik = L * h * Qsik * psi L = 1x 2.1 * 135 x 1 = 356KN
The 4th soil layer is: pebbles, standard value qsik = 140Kpa
The depth is: -13.1 m; The bottom depth is: -14.1 m
Soil thickness h = 1 m
The liquefaction of the soil is psi L = 1
Limit side resistance Qsik = L * h * Qsik * psi L = 1.2566 3704 * 1 * 140 x 1 = 175.9291856 KN
Total limit side resistance Qsk = sigma Qsik = 1223KN
Limit resistance standard value QPK = 8000KN
Limit resistance Qpk = Qpk * As = 8000x.125663704 = 1005.309632 KN
Total lateral resistance design value QsR = Qsk/gamma s = 611 KN
End resistance design value QpR = Qpk/gamma p = 502 KN
The vertical bearing capacity of the base pile is R = Qsk/gamma s + Qpk/gamma p = 12232 + 1005.309632/2 = 1113 KN
─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─
The drill number: ZK2
Pile type: prestressed pipe pile
Coefficient of vertical bearing capacity of pile foundation: K = 2
Pile