家用空调器生产线测试线设计的几个要点.PDF
文本预览下载声明
第 5 卷 第 1 期 制 冷 与 空 调 Vol. 5 ,No. 1
2 0 0 5 年 2 月 REFRIGERA TION AND AIR - CONDITION IN G February 2005
家用空调器生产线测试线设计
的几个要点
申建军 饶荣水 申建民
( ) ( )
河南新飞电器有限公司 河南新乡师范专科学校
摘 要 结合家用空调器室外机生产线测试线的设计实践和生产使用经验 ,就标准室内机、连接软管、测
试电源插座插头及工艺电缆线、低启前区、制热区和制冷区的长度、集电器的滑触线、台车轨道、测试标准
等的设计要点进行讨论。
关键词 家用空调器 生产线 测试线 设计要点
DESIGN OUTL INES OF THE TESTING SYSTEM OF RESIDENTIAL
AIR CONDITIONER ASSEMBL E L INE
SHEN Jianjun RAO Rongshui SHEN Jianmin
( ) ( )
Henan Xinfei Electric Co. Ltd. Henan Xinxiang Teachers Technological Academy
ABSTRACT Based on the design practice and operation experience of the testing system of
residential air conditioner outdoor units , several design outlines , including standard indoor u
nits , connecting soft pipe , testing power supply socket and cable , low voltage start resign ,
heating resign and the cooling resign length , trolley track , testing standard are discussed.
KEY WORDS Residential air conditioner Assemble line Testing system Design outlines
1 前言 一般为 :低压启动、制热、制冷时的电流、电压和电
测试线( ) 功率、送风口和回风口的空气温度、排气口的压力
也称商检系统 是家用空调器室外机
生产线的重要组成部分 ,是室外机出厂前进行性能 等。通过测试 , 即比较性能的一致性 ,发现有不合
检测的最后一道工序和最关键的一道工序。空调 格的 ,及时的挑出、标记 ,避免流入下道工序 , 同时
室外机测试线见图 1 , 图2 为测试线上的台车。 分析原因 ,查找问题所在 ,进行质量控制。测试线
将基本装配好的被测室外机与固定在台车上 所涉及到零部件较多 ,也比较复杂。因此 ,设计性
的标准室内机用连接管连接在一起 ,然后运行 , 以 能优良的家用空调器生产线测试线具有