装配式预制混凝土框架结构拟动力试验研究_范力-吕西林装配式预制混凝土框架结构拟动力试验研究_范力-吕西林.pdf
文本预览下载声明
27 6 V o.l 27 N o. 6
2007 12 JOURNAL OF EARTH QUAKE ENG IN EER ING AND ENG INEER ING V IBRAT ION D ec. 2007
: 1000- 1301( 2007) 06- 0097- 09
范 力, 吕西林, 赵 斌, 张继承
( , 200092)
: 2
, , :
, 1/ 25 ,
, ,
:
: P315. 97 TU 375 TU 317. 1 : A
P seudodynam ic test on jointed p recast concrete fram e structures
FAN L i, LU X ilin, ZHAO B in, ZHANG J icheng
( State K ey L aboratory for D isaster R educt ion in C iv il E ngineering, T ong jiU n ivers ity, Shanghai 200092, C h ina)
Abs tract: T he pseudodynam ic test w as condu cted on two precast concrete fram e structuresw ith one f loor and double
span s, wh ich w ere form ed by the bean- to-co lum n connection w ith rubber cu shion and bo lt, to investigate their seis-
m ic behaviors including the failure pattern, strength, stiffness, hysteret ic ch aracteristic and energy d issipat ion, et
al. T he test results show th at th is k ind o f precast concrete stru ctures can g ive satisfactory seism ic p erform ance
w hen drift arrives at 1/ 25 the stru ctures still h ave rem arkable carrying capac ity. The beam- to-column connection s
w ith rubber cushion and bo lt work w ell and the fa ilure ru le of the stru ctures is du ctile co lum n bend ing failure.
K ey w ord s: precast concrete jo inted connection pseudodynam ic test earthquake resistance fram e stru cture
187 5 6 11, W illiam H enry L asce ll 215 1 / Improvem ent in the con stru ction
of bu ildings0, , L ascell, M o rris
[ 1]
, 70
, PR ESSS( Precast seism ic str
显示全部