文档详情

主发电机试验程序.pdf

发布:2017-06-02约5.15千字共4页下载文档
文本预览下载声明
主发电机试验程序 THE PROCEDURE FOR THE TEST OF MAIN GENERATORS 1. 冷态绝缘电阻测量记录 Insulation Resistance In Cold Condition 2. 主配电板保护报警试验 protection device of main switchboard Ⅰ)过载保护 Overload protection 选择性卸载Prefered trip 长延时L.T. delay 短延时S.T. delay 瞬时MOMENTARY Ⅱ)欠压保护Under Voltage Protection Ⅲ)逆功率保护 Reverse power protection 3. 主柴油发电机组安全报警试验 Safety function alarm test of main D/G set 滑油进口低压报警 L.O. inlet low pressure alarm 滑油进口高温报警 L.O. inlet high Temp. alarm 滑油滤器压差高报警 High diff. Press. of L.O. filter, alarm 燃油滤器压差高报警 High diff. Press. of F.O. filter, alarm 滑油循环柜低位报警 L.O. circulation tank low level, alarm 燃油进口低压报警 F.O. inlet low pressure alarm 高压油管泄漏高位报警 F.O. leak tank high level alarm 淡水进机压力低报警 H/T F.W. inlet Low pressure, alarm 淡水出机温度高报警 H/T F.W. outlet high Temp, alarm 空冷器海水进口温度高 A/C S.W. inlet high Temp alarm 起动空气低压报警 Start air low pressure, alarm 第 1 页 共 4 页 控制空气进口低压报警 Control air inlet low pressure, alarm 增压器出口高温报警 Exhaust gas outlet high Temp, alarm 增压器进机高温报警 EXH. Gas T/C inlet high Temp, alarm 增压器滑油进机低压报警 L.O. T/C inlet low pressure, alarm 发电机前轴承高温报警 Fore bearing of gen. high Temp, alarm 发电机后轴承高温报警 Aft. Bearing of gen. high Temp, alarm 发电机绕组高温报警 Generator winding high temp. Alarm 盘车装置连锁 Turning gear interlock 预润滑油泵故障 Prime L.O. Pump failure 起动故障 Start failure 手动应急停车 Manual emergency stop 柴油发电机电源故障 D/G power failure 柴油发电机停车电磁阀异常报警 D/G stop solenoid valve innormal 滑油进口压力过低报警并停车 L.O. press. too low , alarm and stop 冷却淡水出口温度太高报警并停车 F.W. Temp. outlet too high, alarm and stop 超速停车 Over speed stop auto. 4. 主柴油发电机组冷态起动试验 Main D/G set start test under cold condition 5. 主汇流排故障 main bus failure 5 seconds delay 汇流排高压备用机组自动投入 105%(473V) bus voltage high then the stand-by g