冷却塔与节能 罗金枝,侯红立 上海金日冷却设备有限公司,上海 邮编: 201609 摘要:循环冷却水系统是各工业甚至民用高档建筑能耗的大户,年耗电量约 30 亿 kW.h ,其节能效果对工业企业的节能影响甚大。冷却塔是循环冷却水系统的关键设 备,可以通过降低冷却塔的供水扬程,提高冷却塔的热效率实现节能,也可通过对 在役老化的冷却塔的改造实现节能。 关键词: 冷却塔; 节能; 挖潜改造 Cooling tower and energy conservation Lutherlo , HOU Hong-li (Shanghai Kingsun cooling equipment Co.,Ltd) Abstract: The circulating cooling water system is wide for various industrial field even civil upscale construction, it is the energy consumption wealthy and powerful family , the year power consumption approximately about 3 billion kW/h, its energy conservation effect is really big to Industrial energy conservation influence. The cooling tower is the circulating cooling systems key equipment, may through reduce the cooling tower water supply lifting, enhances the cooling tower the thermal efficiency, may also through tap the old tower’s latent potentialities alteration to realize the energy conservation. Key word: cooling tower , energy conservation ,tapping latent potentialities alteration 工业循环水遍布各行各业,包括空调制冷等,循环水量每小时数以亿吨计。若 按每小时1 亿吨计算,则年耗电量30 亿kW/h ,在当前“节能减排”形势下,“冷却 塔与节能”这个课的研究,倡导并推行改造计划,刻不容缓。 冷却塔的高效低耗能是冷却塔技术发展中永恒不变的目标。冷却塔与节能有两 种含义,一是强调冷却塔的研究,优化冷却塔配件如填料、配水、收水器等,改善 和完善冷却塔的设计方法,如流场的分析,配水配风的均匀性,冷却塔精准的气动 计算等,从而提高效率,降低能耗。二是对目前在运行的数量庞大的冷却塔开展挖 潜改造,提高效率降低能耗。笔者认为通过以下途径实施冷却塔节能: 1.降低冷却塔的供水扬程 冷却塔的能耗除电机外,还有热水送上配水系统的水泵功耗,其耗电量远大于 风机,以4000m3/h (Δt=10 ℃,τ=28 ℃)循环水为例,风机轴功率耗电为137kW/h, 3 而 把 4000m /h 的 水 提 升 至 10m 扬 程 的 水 泵 所 耗 的 电 能 为 1.06 * 4000 / 3600 *1000 *10 =167.8kW/h ,比风机耗电多了22.4% ,若能降低2.0m 的 102 * 0.8 * 0.86 扬程,可节约电耗约33kW/h,这是个不小的数值。众所周知,降低进风口高度、减 少供水管道的阻力和采用低压喷嘴都可以降低水泵的扬程。为了实现上述目标,笔 者分别进行进风口型式(包括不同的百叶及导流沿等)和低压喷头的配水均匀度的 试验。实验证明,当风量不变,随着进风口降低,进风流速提高,进