AWS.D1.1.2000 Structural Welding Code-Steel related.pdf
文本预览下载声明
AWS D1.1 Structural Welding Code:
You Specify It- Do You Know What It Really Says?
Wesley J. Oliphant, PE, AWS-CWI, F.SEI, F.ASCE
ReliaPOLE Inspection Services Company, LLC
1
AWS D1.1 2010
Structural Welding Code - Steel
2
“All welding shall be done in conformance with AWS D1.1”
? a minimum mandatory welding requirement
? for welded structures made from commonly used carbon
and low alloy constructional steels (i.e. typical structural
buildings).
IS THAT ENOUGH FOR THE HIGH PERFORMANCE, NON-
REDUNDANT, FRACTURE CRITICAL WELDING, WE REQUIRE
IN A TYPICAL TUBULAR STEEL TRANSMISSION POLE DESIGN?
AWS D1.1 2010
Structural Welding Code - Steel
3
Poles you purchase should be fabricated to a standard
that exceeds the MINIMUM AWS D1.1 requirements.
AWS D1.1 2010
Structural Welding Code - Steel
4
Consists of (540) Pages organized into:
? (8) “Clauses” (Chapters)
? (9) “Normative” Annexes
? (12) “Informative” Annexes
? Commentary
? Index
You have to read it to
know what’s in it!
AWS D1.1 2010
Structural Welding Code - Steel
Let’s look a the Eight Chapters called “Clauses” of AWS D1.1:
Clause 1: General Requirements
? Basic Information on the scope and limitations of the code,
? Key definitions, and,
? Identifies the major responsibilities of the parties involved with steel
fabrication.
5
AWS D1.1 2010
Structural Welding Code - Steel
AWS D1.1: Paragraph 1.4 Responsibilities:
“The Engineer” (meaning the Owner or Owner’s Engineer) “shall specify”. . .:
? Code Requirements
? All NDT Requirements
? Any verification inspection required (other than fabricator’s inspection)
?Weld acceptance criteria (if different from clause 6 of the code)
? CVN toughness criteria for weld metal, base metal, and/or HAZ when
required.
?Whether the structure is statically or cyclically loaded
? All additional requirements not specifically addressed in the code
? Responsibilities of the parties involved.
6
AWS D1.