Application Notes
Relays
Electromechanical Relays
A member of the ZETTLER Group
www.ZETTLER
Defi nitions and Application Notes
Air distance Switching high loads creates arcs; these arcs may not extinguish
➝ Clearance before the movable contact of a ➝ change-over relay touches
the opposite contact. The intrinsically insulated outer contacts
All-or-nothing relay are then connected by the arc; this leads to short circuits (e.g.
Electrical relay whose ➝ input energizing quantity is either within in the applications shown below). This problem can be avoided
the operative range or zero; ➝ wave form of coil energization. by using a separate relay which interrupts the circuit before
the change-over relay switches and which closes the circuit
Ambient temperature (in use) afterwards.
Temperature, measured directly near the relay. The maximum
allowed value may not be exceeded, otherwise there is the
danger of lasting damage (e.g. reduced contact force or over-
heating of the energized coil).
Ambient temperature (storage and transport)
The maximum allowed value may not be exceeded, otherwise
there is the danger of lasting damage.
Application guidelines
Very diff erent loads (e.g. high load and measuring signal)
shall not be switched by the same relay. ➝ Contact erosion
from switching high loads may pollute the low level switching
contacts.
The actual contact load shall not be lowe