【精选】202_用于低压卤素灯泡的电子变压器规格要求10_2.pdf
文本预览下载声明
错误!未指定书签。 Page
Paulmann Requirements 202
1/8
Save date Vers.
Electronic transformers for low
27/06/2013 12/3
voltage halogen bulbs 11:19:00
1. Aim:
Minimum requirements for PAULMANN or Nice Price, TIP and ECO
electronic transformers for low voltage halogen bulbs
目的:柏曼品牌或NP 牌,TIP 版及 ECO 牌电子变压器用于低压卤素灯的最低标准要求
2. Scope / competency: 范围/适用部门
OEK, PCO, PD, QA, SEK, supplier
3. Abbreviations: 部门缩写
OEK = Operative purchase department 执行采购部
PCO = Paulmann China Office 柏曼中国代表处
PHO = Paulmann Head Office 柏曼德国总部
QA = Quality Assurance 品质部
SEK = Strategic purchase department 战略采购部
4. Additional necessary requirements 其他要求
4.1. 110_Ban of PAH.doc PAH禁令
4.2. 701_Creating of mounting instructions.pdf安装说明书设计标准
4.3. 702_B08_CD_Requirement_mounting_instructions_vXX.pdf安装说明书的制作范本
4.4. 704_Safety instructions electronic transformers: 507000197.pdf 电子变压器安全说明书
4.5. 705_Packing production General requirements.pdf包装产品的通用要求
4.6. 706_Specification article packing.pdf产品包装的规格要求
4.7. 708_E01_CD_Requirement_type_labels.pdf 型号标签的要求
5. General 常规要求
5.1. Electronic transformers must be produced in accordance with the European
directives
Low voltage directive 2006/95/EG
EMC directive 2004/108/EG
RoHS directive 2002/95/EC
ErP directive Draft not published, still under discussion.
ErP 指令草案没有公布,仍在讨论之中。
5.2. Electronic transformers lamps must be in accordance with the European
standards 电子变压器灯具的生产需符合相应的欧洲指令
EN 61047 DC or AC supplied electronic step-down converters for filament lamps - Performance
requi