摘要:地源热泵是利用地球表面浅层水源(如地下水、河流和湖泊)和土壤源中吸收的太阳能和地热能,并采用热泵原理,既可供热又可制冷的高效节能空调系统。
水环热泵空调系统是指小型的水/空气热泵机组的一种应用方式,即用水环路将小型的水/热泵机组并联在一起,形成一个封闭环路,构成一套回收建筑物内部余热作为其低位热源的热泵供暖、供冷的空调系统。典型的水环热泵空调系统由三部分组成:(1)室内的小型水/空气热泵机组;(2)水循环环路;(3)辅助设备(如冷却塔、加热设备、蓄热装置等)。
关键词:地源热泵 水环热泵
Abstract : ground source heat pump is the use of shallow water in the earths surface ( such as groundwater, rivers and lakes) absorption of solar energy and geothermal energy and soil sources, and the use of heat pump principle, not only energy efficient air conditioning system of heating and cooling.
Water loop heat pump air conditioning system is a kind of application mode of small water / air heat pump units, namely water loop will be small water / heat pump units connected in parallel, a closed loop is formed, a set of recycling building waste heat as heat pump heating of the air conditioning system, low-level heat source cooling. Typical water loop heat pump air conditioning system is composed of three parts: ( 1 ) the small water / air heat pump units; ( 2 ) the water cycle loop; ( 3 ) auxiliary equipment ( such as cooling tower, heating equipment, heat storage devices ).
Keywords : ground source heat pump water loop heat pump
中图分类号:TM925.12文献标识码:A 文章编号:2095-2104(2012)
工程概况
本工程为一个综合性的商业区,建筑形态多样,包含:高层办公、多低层商业、地下商店、下沉广场和2层地下车库。总建筑面积:264701.82㎡。本项目地下二层为车库,部分兼做人防设施;地下一层至三层为商业;主要为餐饮和商铺;四层为影院和KTV。并有一栋高层综合楼,一、二层为商铺,四-六层为办公。
设计参数
室内设计参数
表1
冷热源
区域一、区域二为地源热泵系统。区域三、区域四为地源热泵+水环热泵系统。
冷热源机房均位于地下一层。四个区域夏季空调冷源均采用螺杆式地源热泵机组以及离心或螺杆式水冷机组共同提供。水冷机组主要负担冷负荷与经土壤热平衡后热泵机组能提供的制冷量间的差值。四个区域冬季空调热源均采用螺杆式地源热泵机组提供。
热源由锅炉提供,供回水热水温度为65--60℃。锅炉由动力专业设计。
表 2:一二期负荷汇总表
空调风系统
1. 地源热泵系统区域:
商业裙楼中超市,电影院等为大空间区域采用全空气系统,为了提高该区域的空气品质,空调箱设有粗、中效两级过滤段,以及配备加热段,表冷段,送风机段,回风段,及排风段等。空调机房按照防火分区分别设置。空调区域气流组织为上送上回形式。
大部分商业区域(包括地下一层)均采用风机盘管加新风系统。气流组织为上送上回形式。经过处理的新风直接送入房间内,室内设置新风口,在过渡季节可单独开启新风系统将新风送入室内。新风空调箱采用定(正)压变频调速控制变风量运行。
值班室、消防控制中心、电梯机房等另外设分体空调。
2. 水环热泵系统区域:
根据商