110kv变电站设计论文分析.doc
文本预览下载声明
110KV变电站电气部分设计
摘 要
本说明书以110kV地区变电站设计为例,论述了电力系统工程中变电站部分电气设计(一次部分)的全过程。通过对变电站的主接线设计,站用电接线设计,短路电流计算,电气设备动、热稳定校验,主要电气设备型号及参数的确定,运行方式分析,防雷及过电压保护装置的设计,电气总平面及配电装置断面设计和无功补偿方案设计,较为详细地完成了电力系统中变电站设计。
限于毕业设计的具体要求和设计时间的限制,本毕业设计只对变电站电气一次部分做了较为详细的理论设计,而对其电气二次部分并没有涉及,这有待于在今后的学习和工作中进行研究。
关键词:
ABSTRACT
The statement about the 110kv transformer area substation design, discussed some electrical transformer substation design (one part) in power systems engineering of the entire process. Through the main transformer stations wiring design, stations wiring design stations, short circuit current calculations, check electrical equipment moving and thermal stability, set the main electrical equipment models and the parameters, the operating mode, design over-voltage protection and mine devices , design general electric graphic and distribution devices flood, and without power compensation. Completed substation design in power system,lastly.
Limited to the specific design requirements and design time of constraints, the design only is a part of the electrical transformer stations, and its second part did not involve, which research it in future study and work.
KEY WORDS: Substation, Short circuit currents , Moving stability,Thermal stability
目 录
I
ABSTRACT III
1绪 论 1
1.1选题背景和意义 1
1.1.1选题背景 1
1.1.2选题意义 1
1.2原始资料 1
1.2.1分析本变电站在电力系统中的作用 1
1.2.2建设规模 1
1.2.3环境情况 1
1.2.4线路阻抗 2
1.3所做工作 2
1.3.1分析原始资料 2
1.3.2 拟定主接线方案 2
1.3.3短路电流计算 2
1.3.4主要电器选择 2
1.3.5其他计算和设计 3
1.3.6绘制电气主接线图 3
本章小结 3
2电气主接线设计 4
2.1主变压器的选择 4
2.1.1主变压器台数的确定 4
2.1.2主变压器容量的确定 4
2.1.3主变压器相数的确定 5
2.1.4主变压器绕组数和接线组别的确定 5
2.1.5主变压器调压方式的确定 5
2.1.6主变压器冷却方式的确定 6
2.1.7主变压器型号的确定 6
2.2 主接线初步方案的拟订及技术比较 6
2.2.1 110kV电压侧接线 6
2.2.2 10kV电压侧接线 9
2.3方案经济比较 10
2.4主接线最终方案的确定 12
2.5站用变接线设计 13
2.5.1选择变压器 13
2.5.2接线方案确定 13
本章小结 13
3短路电流计算 14
3.1短路故障产生的原因 14
3.2 短路故障的危害 14
3.3 短路电流计算的目的 15
3.4短路电流计算的内容 16
3.4.1短路点的选取 16
3.4.2短路时间的确定 16
3.4.3短路电流的计算 16
3.5短路电流计算方法 16
3.5.1标幺值法 16
3.5.2 有名值法 16
3.6三相短路电流周期分量起始值的计算 16
3.6.1短路电流计算
显示全部