文档详情

《LCL滤波并网逆变器的分裂电容法电流控制.pdf》.pdf

发布:2015-10-31约字共6页下载文档
文本预览下载声明
第 28 卷 第 18 期 中 国 电 机 工 程 学 报 Vol.28 No.18 Jun. 25, 2008 36 2008 年 6 月 25 日 Proceedings of the CSEE ©2008 Chin.Soc.for Elec.Eng. 0258-8013 (2008) 18-0036-06 TM 46 A 470 40 文章编号: 中图分类号: 文献标识码: 学科分类号: ⋅ LCL 滤波并网逆变器的分裂电容法电流控制 沈国桥,徐德鸿 (浙江大学电气工程学院,浙江省 杭州市 310027) Current Control for Grid-connected Inverters by Splitting the Capacitor of LCL Filter SHEN Guo-qiao, XU De-hong (College of Electrical Engineering, Zhejiang University, Hangzhou 310027, Zhejiang Province, China) ABSTRACT: A novel control strategy is proposed based on a 次小于 2% ,35 次以上小于 0.3% 。 new current feedback for grid-connected voltage source 为抑制开关频率输出电流谐波,LCL滤波器在 inverters (VSI) with an LCL-filter. The strategy “split” the 电压源PWM控制并网逆变器中成为首选,因为它与 capacitor of LCL-filter into two parts, and the current flowing 单电感L滤波器相比,对电流高频分量具有更强的 between these two parts is measured and used as the feedback of a current regulator to stabilize and improve the system 抑制能力[1-2],但LCL滤波器具有三阶系统特性,更 performances. By this way, the inverter control system is 易引起输出振荡,因而,对逆变系统电流控制的设 simplified from third-order to first-order, and the close loop 计提出了更高的要求。 control system can easily be optimized for minimum 滞环PWM 电流控制的问题在于其开关频率、损 steady-state error and current harmonic distortion. The 耗和控制精度受滞环宽度的影响[3-5] 。传统的比例积 characteristics of the inverter system with the proposed controller are investigated and compared with the traditional 分调节(PI) 固定频率PWM控制存在输出电流的稳态 strategy. The new current control strategy has been 误差较大,电流谐波难以抑制的缺点。引入电网电 experi
显示全部