TURBINE GLAND SEAL SYSTEMS – ENGINEERING DATA
BULLETIN # PVSTGS PAGE 1 OF 3
GENERAL
These systems generally consist of single- or two-stage
100% capacity ejectors, single 100% surface-type pre- or
inter/aftercondensers, suction steam isolation valves and
interconnecting vacuum piping. They are designed to
remove air steam from the turbine gland seal area to
prevent air from flowing into the condenser on condensing
steam turbines.
• Power Plant Turbine Requirements
MODEL PC23E GLAND SEAL SYSTEM
with Quickcheck® Steam Chest
Gland Steam ejectors designed to meet the turbine
manufacturers specified requirements for dry air leakage and water vapor at the specified
vacuum level. These systems are typically two-stage units with inter- aftercondenser, or a
single-stage unit with pre-condenser, depending on the operating pressure requirement.
Condensate is the most common cooling medium for the condensers.
• Commercial Standard Requirements
Gland Steam ejectors designed to meet typical HVAC Standards should handle the air leakage
specified plus water vapor at the pressure specified by the turbine manufacturer. Single-
stage, single-element systems with pre- or aftercondenser are typical. Also common is one,
single-stage ejector only on smaller turbines. Condensate or cooling water is used for the
condensers.