某干气线法兰焊接接头开裂原因分析.pdf
经验交流
ExperienceExchange
某干气线法兰焊接接头
开裂原因分析
刘春辉
(中石化(天津)石油化工有限公司装备研究院,天津300270)
摘要:某加氢裂化装置开车过程中干气线的法兰焊接接头发生开裂,本文通过宏观检验、
金相检验、硬度检测、化学成分分析等方法,对管线泄漏原因进行了分析研究。结果表明:该管
线法兰的化学成份不符合设计标准要求,在低温湿硫化氢环境下发生了应力腐蚀开裂。
关键词焊接接头应力腐蚀开裂
中图分类号:TE9文献标识码:ADOI:10.13726/j.cnki.11-2706/tq.2024.06.103.03
AnalysisofCrackingReasonsforFlangeWelding
JointsinaCertainDryGasLine
LIUChun-hui
(EquipmentResearchInstituteofSinopec(Tianjin)PetrochemicalCo.,Ltd.
TianjinBinhaiNewArea,Tianjin300270,China)
Abstract:Duringthestart-upofahydrocrackingunit,theflangeweldingjointofthedrygas术技
pipelinecracked.Thisarticleanalyzedandstudiedthecausesofpipelineleakagethroughmethodssuch
asmacroscopicinspection,metallographicexamination,hardnesstesting,andchemicalcomposition
analysis.Theresultsindicatethatthechemicalcompositionofthepipelineflangedoesnotconformtothe
requirementsofdesignstandard,andstresscorrosioncrackingoccurredinalow-temperaturewethydrogen
sulfideenvironment.
Keywords:weldedjoint;stresscorrosion;dehiscence
0引言1检验与分析
某加氢裂化装置开车过程中,车间人员闻到1.1宏观检验
低压分离器附近的硫化氢气味浓重,经检查发现低
宏观观察法兰焊接接头,无鼓胀变形,裂纹
压分离器顶部干气线压控付线阀上的法兰焊接接头
位于法兰侧熔合线附近,沿圆周方向开裂,为穿透
发生了开裂。该干气线于1999年10月投用,规格¢
性裂纹,外壁长约80mm,如图1所示。沿轴向剖开
89×7mm,管线材质为碳钢,法兰为对焊法兰,材
法兰接头后,发现裂纹断口较粗糙,无金属光泽,
#
质为20,操作压力2.0MPa,操作温度40~50℃,介