28 3 Vol.28 No.3
2012 5 Power System Engineering 44
1005-006X(2012)03-0044-03
1000 MW
1 2 1 1 3
1.2.3.
1000 MW
1000 MW
TK223.26 A
Type Selection Analysis of IDF for Supercritical 1000MW Coal-Fired Power Unit
WANG Ni-ni, GAO Ming, LIU Jie, QU Ning, LIU Jia-hao
Abstract The type selection of induced-draft fan (IDF) for 1000MW supercritical power unit is discussed. Based on
performance analysis of three kinds of typical fans, two different system configurations are put forward according to
boiler gas air system requirements resulting from the addition of desulphurization and denitrification system, and
analyzes technical characteristics of each