文档详情

1000MW超超临界燃煤发电机组引风机选型方案分析-ResearchGate.PDF

发布:2018-12-09约1.09万字共4页下载文档
文本预览下载声明
See discussions, stats, and author profiles for this publication at: /publication/325280591 Type Selection Analysis of IDF for Su percritical 1000MW Coal-Fired Power Unit Article  in   Power System Technology · May 2012 CITATIONS READS 0 5 2 authors, including: Ming Gao Shandong University 59 PUBLICATIONS   317 CITATIONS    SEE PROFILE Some of the authors of this publication are also working on these related projects: thermal permance for large-scale wet cooling towers View project flow induced noise in centrifugal pumps View project All content following this page was uploaded by Ming Gao on 22 May 2018. The user has requested enhancement of the downloaded file. 28 3 Vol.28 No.3 2012 5 Power System Engineering 44 1005-006X(2012)03-0044-03 1000 MW 1 2 1 1 3 1.2.3. 1000 MW 1000 MW TK223.26 A Type Selection Analysis of IDF for Supercritical 1000MW Coal-Fired Power Unit WANG Ni-ni, GAO Ming, LIU Jie, QU Ning, LIU Jia-hao Abstract The type selection of induced-draft fan (IDF) for 1000MW supercritical power unit is discussed. Based on performance analysis of three kinds of typical fans, two different system configurations are put forward according to boiler gas air system requirements resulting from the addition of desulphurization and denitrification system, and analyzes technical characteristics of each
显示全部
相似文档