OPERATION PROCEDURE MANUAL FOR TYPE C 125TON AUTOMATIC SPIDER 1 CONTENT 1.SECTION 1 – INTRODUCTION 3 2. SECTION 2 – OPERATION 4 3. SECTION 3 – INSTALLATION 5 4. SECTION4–MAINTENANCE 6 5.SECTION5–APPENDIX 7 2 1 Section1 – introduction THIS MANUAL INCLUDES OPERATION AND MAINTENANCE INSTRUCTIONS FOR TYPE C 125TON AUTOMATIC SPIDER WITH COMPLETE PRATS LISTS. Product description : TYPE C 125TON automatic spiders are suitable for the tubing range from 2-3/8” to 5” (60.33mm-127mm). The gate opening is 6” (152mm). The bowl opening is 6 5/8”(168mm) It is designed for pneumatic or manually operating. Specifications for Model “C” Spiders – 125Ton SPECIFICATIONS C HEIGHT 17-1/8 (435mm ) BASE DIMENSION 18 1/4x18 7/8 (463mm x 480mm) GATE OPENING 6 (152.4mm) BOWL OPENING 6-5/8 (168.3mm) TUBULAR RANGE 2-3/8, 2-7/8, 3-1/2,4 ,4- 1/2, 5” MAXIMUM LOAD 165,000Lbs (125Ton) CAPACITY 3 2. Section 2 – operation Preparation In order to operate the tubing spider correctly, the following step points should be prepared. 1. Choice suitable slip insert according to gripping pipe diameter and install correctly. 2. Check the outlet and inlet of cylinder make sure no any obstacles and connect hose to air resource. 3. Check the air pressure range, normally at 0.8 – 1.2 Mpa 4. The cylinder’s working pressure at 0.6 – 0.8 Mpa 5. Be sure to keep air source closing when lifting the slip with manual.