民用负荷对配电网电能质量的影响.doc
文本预览下载声明
民用负荷对配电网电能质量的影响
赵莉华,雷晶晶,荣强
(四川大学 电气信息学院,成都 610065)
摘要:民用负荷的谐波特性使配电网的电能质量问题日益突出。为此,对典型民用负荷的用电原理及谐波特性进行详尽阐述,并进行仿真验证,分析总结出这些民用负荷给配电网造成的电能质量问题,如谐波电流超标、中性线过电流等;在此基础上,采用Fluke430Ⅱ电能质量分析仪对配电网中的典型用户进行了现场测试,实测数据表明配电网的谐波电流超标严重。最后,针对配电网存在的电能质量问题提出了改善措施。
关键词:民用负荷;配电网;电能质量;谐波
中图分类号:TM714 文献标识码:A 文章编号:1001-1390(2015)00-0000-00
Effects of appliance load on power quality in distribution system
Lihua, Lei Jingjing, Rong Qiang
(School of Electrical Engineering and Information, Sichuan University, Sichuan 610065, China)
Abstract:The harmonic characteristics of appliance load have made power quality problems in distribution system become increasingly prominent. Thus, the electricity principles and harmonic characteristics of typical appliance loads are elaborated in detail and simulated, in summary that appliance loads have caused the distribution system some power quality problems, such as excessive harmonic currents, neutral over-current; on this basis, power quality of typical residential loads in distribution system are tested by using power quality analyzer Fluke430Ⅱ, the field measurements show that harmonic currents in distribution system have exceeded the national standard. Finally, some improvement measurements are proposed to solve the power quality problems.
Keywords:appliance load, distribution system, power quality, harmonics
0 引 言
电能质量问题的提出由来已久,在电力系统发展初期,负荷成分比较简单,主要由同步电动机、异步电动机和各种照明设备等线性负荷组成[1];然而从20世纪80年代起,电力电子技术迅速发展,促使快速、连续、精密的电力电子装置在工业及民用设备中得到推广应用,但其自身结构的复杂性和非线性使得工业及民用户甚至整个电网呈非线性化发展趋势,引起各种电能质量问题。为解决这些问题,国家电网公司已于2012年组织北京、天津、山东、上海、江苏、福建和重庆7家单位开展了电能质量在线监测系统试点建设工作,监测系统现已投入试运行。在电能质量监测方面国网公司提出“先高压后低压,先城市后农村,先易后难,同步跟进”的指导原则,各省公司也分别在这个指导原则下,投入了大量人力、物力开展电能质量相关问题的研究工作。考虑到电网运行的可靠性与经济性,国家电网公司将重心放在大工业用户上,为其提供专线供电的同时,也制定有专门的考核指标来考察其电能质量是否合格;而对于量多、面广且分散的民用负荷还少有专门的研究,为此,展开民用负荷对配电网电能质量的影响的研究工作具有现实意义和参考价值。
文章针对家用、市政、公共场合的典型非线性负荷的用电原理及谐波特性进行详尽的分析研究,建模仿真,给出各类民用负荷的电流波形及其频谱分析,利用Fluke430Ⅱ电能质量分析仪对配电网中典型用户进行现场测试。通过对民用负荷对配电网造成的电能质量问题进行理论分析与仿真,表明民